Filtry strzykawkowe z prefiltrem GD/X, niesterylne

Filtry strzykawkowe GD/X przeznaczone są do filtracji próbek lepkich lub trudnych do sączenia o wysokiej zawartości substancji stałych.
Whatman™ GD/X syringe filters are specifically designed for filtration of viscous or otherwise hard-to-filter samples with high solids content.

• Glass fiber prefiltration stack for filtering larger sample volumes with less back pressure build-up
• High loading capacity for samples with high solids content
• Processes three to seven times more sample volume than filters without prefilter
• Nonsterile GD/X filters are available in two diameters: 13 mm and 25 mm, and three pore sizes: 0.2 µm, 0.45 µm, and 5 µm

Sterile GD/X options are also available.

Syringe filter with integrated prefiltration
Constructed of a polypropylene housing with a prefiltration stack of Whatman™ GMF 150 (graded density) and GF/F glass microfiber prefilters, GD/X syringes enable exceptional loading capacity with high flow rates for difficult-to-filter samples. This design prevents the buildup of back pressure typically caused by the blocking of an unprotected membrane.

GD/X syringes are suitable for capillary electrophoresis, HPLC, and UV/VIS sample preparation when dealing with viscous or otherwise difficult-to-filter samples with high solids content.

GD/X membrane options for chemical compatibility
Whatman™ GD/X syringe filters are manufactured with a wide range of membrane materials to support your specific application. Options include:

• Nylon syringe filters
• High-charge nylon syringe filters
• PES syringe filters
• PVDF syringe filters
• PTFE syringe filters
• Polypropylene syringe filters
• Cellulose acetate syringe filters
• Glass fiber syringe filters
• Regenerated cellulose syringe filters
Filtry strzykawkowe z prefiltrem GD/X, niesterylne
Filtry strzykawkowe z prefiltrem GD/X, niesterylne
Whatman™ GD/X syringe filters: Increase throughput from samples with high solid content.
What's the difference? Whatman™ GD/X syringe filters.
Prefilter Material 100% Borosilicate Glass Fiber GMF 150 10 µm: 1 µm GF/F 0.7 µm 
Sterility Non-sterile 
Inlet Connector Female luer lock 
Outlet Connector Male luer 
Housing Pigment free polypropylene (PP) 
Sterilization Autoclave at 1210C (1310C max) at 1 bar (15 psi) for 20 minutes 
Operating pressure max. 6.9 bar (100 psi) 
Flow Direction Flow should enter from the inlet 
Product Product Name Pore size Filtration media Diameter
6870-2502 GD/X 25 mm Syringe Filter; nylon filtration medium; 0.2 µm (150 pcs) 0.2 µm Nylon 25 mm
6870-2504 GD/X 25 mm Syringe Filter; nylon filtration medium; 0.45 µm (150 pcs) 0.45 µm Nylon 25 mm
6870-2550 GD/X 25 mm Syringe Filter; nylon filtration medium; 5.0 µm (150 pcs) 5 µm Nylon 25 mm
6871-1302 GD/X 13 mm Syringe Filter; nylon filtration medium; 0.2 µm (1500 pcs) 0.2 µm Nylon 13 mm
6871-1304 GD/X 13 mm Syringe Filter; nylon filtration medium; 0.45 µm (1500 pcs) 0.45 µm Nylon 13 mm
6871-2502 GD/X 25 mm Syringe Filter; nylon filtration medium; 0.2 µm (1500 pcs) 0.2 µm Nylon 25 mm
6871-2504 GD/X 25 mm Syringe Filter; nylon filtration medium; 0.45 µm (1500 pcs) 0.45 µm Nylon 25 mm
6871-2550 GD/X 25 mm Syringe Filter; nylon filtration medium; 5.0 µm (1500 pcs) 5 µm Nylon 25 mm
6872-1302 GD/X 13 mm Syringe Filter; PVDF filtration medium; 0.2 µm (150 pcs) 0.2 µm Polyvinylidene Difluoride (PVDF) 13 mm
6872-1304 GD/X 13 mm Syringe Filter; PVDF filtration medium; 0.45 µm (150 pcs) 0.45 µm Polyvinylidene Difluoride (PVDF) 13 mm
6872-2502 GD/X 25 mm Syringe Filter; PVDF filtration medium; 0.2 µm (150 pcs) 0.2 µm Polyvinylidene Difluoride (PVDF) 25 mm
6872-2504 GD/X 25 mm Syringe Filter; PVDF filtration medium; 0.45 µm (150 pcs) 0.45 µm Polyvinylidene Difluoride (PVDF) 25 mm
6873-1304 GD/X 13 mm Syringe Filter; PVDF filtration medium; 0.45 µm (150 pcs) 0.45 µm Polyvinylidene Difluoride (PVDF) 13 mm
6873-2502 GD/X 25 mm Syringe Filter; PVDF filtration medium; 0.2 µm (1500 pcs) 0.2 µm Polyvinylidene Difluoride (PVDF) 25 mm
6873-2504 GD/X 25 mm Syringe Filter; PVDF filtration medium; 0.45 µm (1500 pcs) 0.45 µm Polyvinylidene Difluoride (PVDF) 25 mm
6874-1302 GD/X 13 mm Syringe Filter; PTFE filtration medium; 0.2 µm (150 pcs) 0.2 µm Polytetrafluoroethylene (PTFE) 13 mm
6874-1304 GD/X 13 mm Syringe Filter; PTFE filtration medium; 0.45 µm (150 pcs) 0.45 µm Polytetrafluoroethylene (PTFE) 13 mm
6874-2502 GD/X 25 mm Syringe Filter; PTFE filtration medium; 0.2 µm (150 pcs) 0.2 µm Polytetrafluoroethylene (PTFE) 25 mm
6874-2504 GD/X 25 mm Syringe Filter; PTFE filtration medium; 0.45 µm (150 pcs) 0.45 µm Polytetrafluoroethylene (PTFE) 25 mm
6875-1302 GD/X 13 mm Syringe Filter; PTFE filtration medium; 0.2 µm (1500 pcs) 0.2 µm Polytetrafluoroethylene (PTFE) 13 mm
6875-1304 GD/X 13 mm Syringe Filter; PTFE filtration medium; 0.45 µm (1500 pcs) 0.45 µm Polytetrafluoroethylene (PTFE) 13 mm
6875-2502 GD/X 25 mm Syringe Filter; PTFE filtration medium; 0.2 µm (1500 pcs) 0.2 µm Polytetrafluoroethylene (PTFE) 25 mm
6875-2504 GD/X 25 mm Syringe Filter; PTFE filtration medium; 0.45 µm (1500 pcs) 0.45 µm Polytetrafluoroethylene (PTFE) 25 mm
6876-1302 GD/X 13 mm Syringe Filter; polyethersulfone filtration medium; 0.2 µm (150 pcs) 0.2 µm Polyethersulfone (PES) 13 mm
6876-1304 GD/X 13 mm Syringe Filter; polyethersulfone filtration medium; 0.45 µm (150 pcs) 0.45 µm Polyethersulfone (PES) 13 mm
6876-2502 GD/X 25 mm Syringe Filter; polyethersulfone filtration medium; 0.2 µm (150 pcs) 0.2 µm Polyethersulfone (PES) 25 mm
6876-2504 GD/X 25 mm Syringe Filter; polyethersulfone filtration medium; 0.45 µm (150 pcs) 0.45 µm Polyethersulfone (PES) 25 mm
6878-1302 GD/X 13 mm Syringe Filter; polypropylene filtration medium; 0.2 µm (150 pcs) 0.2 µm Polypropylene (PP) 13 mm
6878-1304 GD/X 13 mm Syringe Filter; polypropylene filtration medium; 0.45 µm (150 pcs) 0.45 µm Polypropylene (PP) 13 mm
6878-2502 GD/X 25 mm Syringe Filter; polypropylene filtration medium; 0.2 µm (150 pcs) 0.2 µm Polypropylene (PP) 25 mm
6878-2504 GD/X 25 mm Syringe Filter; polypropylene filtration medium; 0.45 µm (150 pcs) 0.45 µm Polypropylene (PP) 25 mm
6879-2504 GD/X 25 mm Syringe Filter; polypropylene filtration medium; 0.45 µm (1500 pcs) 0.45 µm Polypropylene (PP) 25 mm
6880-1302 GD/X 13 mm Syringe Filter; cellulose acetate filtration medium; 0.2 µm (150 pcs) 0.2 µm Cellulose Acetate (CA) 13 mm
6880-1304 GD/X 13 mm Syringe Filter; cellulose acetate filtration medium; 0.45 µm (150 pcs) 0.45 µm Cellulose Acetate (CA) 13 mm
6880-2502 GD/X 25 mm Syringe Filter; cellulose acetate filtration medium; 0.2 µm (150 pcs) 0.2 µm Cellulose Acetate (CA) 25 mm
6880-2504 GD/X 25 mm Syringe Filter; cellulose acetate filtration medium; 0.45 µm (150 pcs) 0.45 µm Cellulose Acetate (CA) 25 mm
6881-2504 GD/X 25 mm Syringe Filter; cellulose acetate filtration medium; 0.45 µm (1500 pcs) 0.45 µm Cellulose Acetate (CA) 25 mm
6882-1316 GD/X 13 mm Syringe Filter; glass microfiber GF/A filtration medium; 1.6 µm (150 pcs) 1.6 µm Glass Fiber (GF/A) 13 mm
6882-2504 GD/X 25 mm Syringe Filter; regenerated cellulose filtration medium; 0.45 µm (150 pcs) 0.45 µm Regenerated Cellulose (RC) 25 mm
6882-2516 GD/X 25 mm Syringe Filter; glass microfiber GF/A filtration medium; 1.6 µm (150 pcs) 1.6 µm Glass Fiber (GF/A) 25 mm
6883-2504 GD/X 25 mm Syringe Filter; regenerated cellulose filtration medium; 0.45 µm (1500 pcs) 0.45 µm Regenerated Cellulose (RC) 25 mm
6883-2516 GD/X 25 mm Syringe Filter; glass microfiber GF/A filtration medium; 1.6 µm (1500 pcs) 1.6 µm Glass Fiber (GF/A) 25 mm
6884-1310 GD/X 13 mm Syringe Filter; glass microfiber GF/B filtration medium; 1.0 µm (150 pcs) 1 µm Glass Fiber (GF/B) 13 mm
6884-2510 GD/X 25 mm Syringe Filter; glass microfiber GF/B filtration medium; 1.0 µm (150 pcs) 1 µm Glass Fiber (GF/B) 25 mm
6886-1312 GD/X 13 mm Syringe Filter; glass microfiber GF/C filtration medium; 1.2 µm (150 pcs) 1.2 µm Glass Fiber (GF/C) 13 mm
6886-2512 GD/X 25 mm Syringe Filter; glass microfiber GF/C filtration medium; 1.2 µm (150 pcs) 1.2 µm Glass Fiber (GF/C) 25 mm
6887-2502 GD/X 25 mm Syringe Filter; regenerated cellulose filtration medium; 0.2 µm (150 pcs) 0.2 µm Regenerated Cellulose (RC) 25 mm
6888-1327 GD/X 13 mm Syringe Filter; glass microfiber GF/D filtration medium; 2.7 µm (150 pcs) 2.7 µm Glass Fiber (GF/D) 13 mm
6888-2502 GD/X 25 mm Syringe Filter; regenerated cellulose filtration medium; 0.2 µm (1500 pcs) 0.2 µm Regenerated Cellulose (RC) 25 mm
6888-2527 GD/X 25 mm Syringe Filter; glass microfiber GF/D filtration medium; 2.7 µm (150 pcs) 2.7 µm Glass Fiber (GF/D) 25 mm
6890-1307 GD/X 13 mm Syringe Filter; glass microfiber GF/F filtration medium; 0.7 µm (150 pcs) 0.7 µm Glass Fiber (GF/F) 13 mm
6890-2507 GD/X 25 mm Syringe Filter; glass microfiber GF/F filtration medium; 0.7 µm (150 pcs) 0.7 µm Glass Fiber (GF/F) 25 mm
6891-2507 GD/X 25 mm Syringe Filter; glass microfiber GF/F filtration medium; 0.7 µm (1500 pcs) 0.7 µm Glass Fiber (GF/F) 25 mm
6892-2515 GD/X 25 mm Syringe Filter; 934-AH filtration medium; 1.5 µm (150 pcs) 1.5 µm 934-AH 25 mm
6894-1304 GD/X 13 mm Syringe Filter; glass microfiber filtration medium; 0.45 µm (150 pcs) 0.45 µm Glass Microfiber (GMF) 13 mm
6894-2504 GD/X 25 mm Syringe Filter; glass microfiber filtration medium; 0.45 µm (150 pcs) 0.45 µm Glass MicroFiber (GMF) 25 mm
6895-2504 GD/X 25 mm Syringe Filter; glass microfiber filtration medium; 0.45 µm (1500 pcs) 0.45 µm Glass MicroFiber (GMF) 25 mm
6905-2502 GD/X 25 mm Syringe Filter; polyethersulfone filtration medium; 0.2 µm (1500 pcs) 0.2 µm Polyethersulfone (PES) 25 mm
6905-2504 GD/X 25 mm Syringe Filter; polyethersulfone filtration medium; 0.45 µm (1500 pcs) 0.45 µm Polyethersulfone (PES) 25 mm